Flasher Model SlaveThe Slave Flasher offers a simple system for synchronizing the flash rhythms of multiple lights. The Slave Flasher does not have its own flash circuitry. It receives its flash pulse (rhythm) from a connection to a master Flasher so that two or more Slaves can flash synchronously with their master. The master Flasher is a standard Flasher. The Slave Flasher also has a second output to operate our 6-Place Lampchanger to switch to a new lamp when the lamp in the burning position fails. It also provides voltage regulation to the lamp.
Electrical Specifications Input: 4.5 - 16 VDC Voltage Regulation: 12 VDC Output: 60 Watts Reverse Polarity and Short Circuit Protected
Terminal Connections (-) input - (White) (+) input - (Black) Master Flasher connection - (Yellow) on Slave from (Red) on Master Lamp connection - (Red) Lampchanger connection - (Blue) All Slaves must have common Ground connection with Master (White terminals)
| ||||
|
|
|||||